March 2, 2021
Flat Roof Window Glass / Roof Lantern Skylight Flat Rooflight 1500mm x 1500mm
Flat Roof Window Glass / Roof Lantern Skylight Flat Rooflight – 1500mm x 1500mm. Easy 3-step Fitting Guide. Create your roof opening size and upstand 80mm wide using a good quality roofing timber. To assist you with the installation we have provided you the measurements below. &#######xA0; &#######xA0; &#######xA0; Roof Lantern Selection&#######xA0; -&#######xA0;&#######xA0. Timber Kerb Opening&#######xA0;Size. 300mm x 300mm &#######xA0;–>&#######xA0; 100mm x 100mm. 500mm x 500mm&#######xA0; –>&#######xA0; 300mm x 300mm. 1000mm x 1000mm&#######xA0;&#######xA0;–>&#######xA0; 800mm x 800mm. 1200mm x 1200mm&#######xA0; –>&#######xA0; 1000mm x 1000mm. 1500mm x 1000mm&#######xA0; –>&#######xA0; 1300mm x 800mm. 1500mm x 1500mm&#######xA0; –>&#######xA0; 1300mm x 1300mm. 1700mm x 1200mm&#######xA0; –>&#######xA0; 1500mm x 1000mm. 2000mm x 1000mm&#######xA0; –>&#######xA0; 1800mm x 800mm. 2200mm x 1200mm&#######xA0; –>&#######xA0; 2000mm x 1000mm. 2700mm x 1200mm&#######xA0; –>&#######xA0; 2500mm x 1000mm. 3200mm x 1200mm&#######xA0; –>&#######xA0; 3000mm x 1000mm. STEP 2:&#######xA0; &#####x200B;&#####x200B;&#####x200B;&#####x200B;&#####x200B;&#####x200B;&#####x200B. Seal the Lantern to the upstand using a high quality Glazing Silicone; preferrably by using DOWSIL 781 Glazing Silicone. &#####x200B;&#####x200B;&#####x200B;&#####x200B;&#####x200B;&#####x200B;&#####x200B. &#####x200B;&#####x200B;&#####x200B;&#####x200B;&#####x200B;&#####x200B;&#####x200B;Install a Timber Batton to the underside of the lantern to support the bottom pane of the lantern. (Please Note: This is a critical part of the installation Failure to do this may result in the lantern becoming defective and unsafe). Thermolight’ Rooflight Skylight for flat roofs. TRIPLE GLAZED AVAILABLE&#######xA0;ON REQUEST! MADE TO BS EN 12150 STANDARD! Please Note: Other sellers are claiming their product complies to; &#######xA0; AIR PERMEABILITY (EN12207) AND WATER TIGHTNESS (EN12208) – This isnt the case. The’ Thermolight’ &#######xA0;flat rooflight comes&#######xA0;with a high efficiency energy rated glazing, keeping you nice and warm in the winter and suitably cool in the summer. Bring light in to dark spaces without compromising on energy efficiency. Great for use in stair wells, ground floor extensions etc. Top Outer Pane -&#######xA0;6mm softcoat toughened with a 100mm UV Printed black border finsihed with&#######xA0;Beveled Edges. Cavity – 18mm spacer bar with argon gas filling. Inner Bottom Pane – 4mm softcoat toughened. Overall 1.2 u value. We recommend that you fit your thermolight roof light&#######xA0;on a gradient of 40mm in 1000mm to allow any surface water to run off. Prior to fitting your thermolight roof light&#######xA0;your on site joiner will need to form a timber kerb up stand&#######xA0;70mm wide x 150mm high leaving a clear opening between the timbers set in by 100mm from size of the roof light&#######xA0;you order eg 1000mm x 2000mm rooflight set the internal of the timbers to 800mm x 1800mm. Our thermolight rooflight&#######xA0;has a 100mm overhang on all 4 sides to fully cover and overhang the top face of the timber kerb up stand. Your chosen roof covering (Rubber, GRP or felt) should be applied to your roof, up and over the top face of your timber kerb up stand&#######xA0;prior to fitting the roof light. Once&#######xA0;completed you can commence fitting. Apply suitable glazing silicone to the top of the timber kerb up stand&#######xA0;without compromise. Bed down your thermolight roof light&#######xA0;on the silicone beads with equal pressure ensuring no air bubbles are left. Fit a timber baton&#######xA0;support internally under&#######xA0;the inner pane as shown in the image. This is a critial part of the installation. Failure to fit&#######xA0;this will&#######xA0;result in your Lantern becoming defective, falling parts may occur which can cause injury. This is depending on your location in the country! Measure&#####x200B;&#####x200B;&#####x200B;&#####x200B;&#####x200B;&#####x200B;&#####x200B. Any product you return must be in the same condition you received it and in the original packaging. Please keep the receipt. See our other items. Flat Roof Glass / Roof Lantern Skylight Flat Rooflight Lantern – 1500mm x 1500mm. STEP 1:&#######xA0; Create your roof opening size and upstand 80mm wide using a good quality roofing timber. &#######xA0; &#######xA0; &#######xA0; Roof Lantern Selection&#######xA0; -&#######xA0;&#######xA0; Timber Kerb Opening&#######xA0;Size. 300mm x 300mm&#######xA0; -&#######xA0; 100mm x 100mm. 500mm x 500mm&#######xA0; -&#######xA0; 300mm x 300mm. 1000mm x 1000mm&#######xA0;&#######xA0;-&#######xA0; 800mm x 800mm. 1200mm x 1200mm&#######xA0; -&#######xA0; 1000mm x 1000mm. 1500mm x 1000mm&#######xA0; -&#######xA0; 1300mm x 800mm. 1500mm x 1500mm&#######xA0; -&#######xA0; 1300mm x 1300mm. 1700mm x 1200mm&#######xA0; -&#######xA0; 1500mm x 1000mm. &#####x200B;&#####x200B;&#####x200B;&#####x200B;&#####x200B;&#####x200B;&#####x200B;2000mm x 1000mm&#######xA0; -&#######xA0; 1800mm x 800mm. 2200mm x 1200mm&#######xA0; -&#######xA0; 2000mm x 1000mm. 2700mm x 1200mm&#######xA0; -&#######xA0; 2500mm x 1000mm. 3200mm x 1200mm&#######xA0; -&#######xA0; 3000mm x 1000mm. STEP 2:&#######xA0; &#####x200B;&#####x200B;&#####x200B;&#####x200B;&#####x200B;&#####x200B;&#####x200B;Seal the Lantern to the upstand using a high quality Glazing Silicone; preferrably by using DOWSIL 781 Glazing Silicone. &#######xA0;STEP 3:&#######xA0; &#####x200B;&#####x200B;&#####x200B;&#####x200B;&#####x200B;&#####x200B;&#####x200B;Install a Timber Batton to the underside of the lantern to support the bottom pane of the lantern. Prior to fitting your thermolight roof light&#######xA0;your on site joiner will need to form a timber kerb up stand&#######xA0;70mm wide x 150mm high leaving a clear opening between the timbers set in by 100mm from size of the roof light&#######xA0;you order eg 1000mm x 200mm rooflight set the internal of the timbers to 800mm x 1800mm. &#######xA0;’Thermolight’ rooflight skylight for flat roofs. All Sizes Shown are External Sizes. The’ Thermolight’ &#######xA0;flat rooflight with high efficiency energy rate glazing, keeping you nice and warm in the winter and suitably cool in the summer. Bring light in to dark spaces with compromising on energy efficiency. Top Outer Pane &#######xA0;-&#######xA0;6mm softcoat toughened with 100mm black border. Cavity&#######xA0; – 18mm spacer bar with argon gas filling. Inner Bottom Pane &#######xA0;- 4mm softcoat toughened. Prior to fitting your thermolight roof light&#######xA0;your on site joiner will need to form a timber kerb up stand&#######xA0;70mm w x 150mm h leaving a clear opening between the timbers set in by 100mm from size of the roof light&#######xA0;you order eg 1000mm x 200mm rooflight set the internal of the timbers to 800mm x 1800mm. Our thermolight roof light&#######xA0;has a 100mm overhang on all 4 sides to fully cover and overhang the top face of the timber kerb up stand. Your chosen roof covering (rubber, GRP or felt) should be applied to your roof, up and over the top face of your timber kerb up stand&#######xA0;prior to fitting the roof light. Once&#######xA0; complete you can commence fitting. The item “Flat Roof Window Glass / Roof Lantern Skylight Flat Rooflight 1500mm x 1500mm” is in sale since Tuesday, January 7, 2020. This item is in the category “Home, Furniture & DIY\DIY Materials\Roofing, Tiles & Shingles\Roof Sheets & Panels”. The seller is “thermolightglass” and is located in Doncaster, South Yorkshire. This item can be shipped to United Kingdom.
- MPN: Does Not Apply
- Featured Refinements: Flat Roof
- Brand: Thermolite
- Type: Roof Panel